Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Fit of All-Ceramic Posterior Fixed Partial Denture Frameworks in Vitro
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 27 , Issue 6
November/December 2007

Pages 567-575


Fit of All-Ceramic Posterior Fixed Partial Denture Frameworks in Vitro

Andreas Bindl, Dr med dent/Werner H. Mörmann, Dr med dent, Prof


PMID: 18092451
DOI: 10.11607/prd.00.0769

The objective of this study was to evaluate, by scanning electron microscopy, the marginal and internal fit of all-ceramic three-unit fixed partial denture (FPD) frames fabricated by computer-assisted design/computer-aided machining (CAD/CAM) and CAM techniques using blocks of infiltration ceramic, high-strength yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) zirconia sinter ceramic, high-strength dense sintered Y-TZP zirconia ceramic, and glass ceramic. Slip-cast infiltration ceramic was used as a traditional control. The cementation interface widths of the FPD frame copings on butt (A) shoulders of Cerec In-Ceram zirconia (A1, 53 ± 17 µm) were smaller than those of slip-cast In-Ceram zirconia (A6, 113 ± 25 µm). Cerec Y-TZP zirconia (A2, 53 ± 9 µm) and DCS Y-TZP zirconia (A4, 32 ± 6 µm) interfaces were both significantly smaller than those of Cercon Y-TZP zirconia (A5, 120 ± 6 µm). Internally, A2 (103 ± 14) interfaces were smaller than A4 interfaces (144 ± 15 µm). On chamfer shoulders (B), Cerec Y-TZP zirconia (B1, 71 ± 5 µm) interfaces were smaller than Cercon interfaces (B2, 129 ± 38 µm); internally, B1 (80 ± 11 µm) interfaces were smaller than B2 interfaces (130 ± 12 µm). CAD/CAM produced better marginal and internal accuracy of fit compared to slip casting and CAM techniques. (Int J Periodontics Restorative Dent 2007;27:567–575.)


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 